{"product_id":"rosslare-ac-q41hb-standalone-pin-keypad","title":"Rosslare AC-Q41HB Standalone PIN Keypad","description":"\u003cdiv style=\"border: 1px solid #d9dbea; background: #f7f7fb; padding: 16px; margin-bottom: 22px;\"\u003e\n  \u003cp style=\"margin: 0 0 6px;\"\u003e\u003cstrong\u003eBest For\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp style=\"margin: 0;\"\u003eSingle-door access points at offices, warehouses, apartment common areas and gates that need locally managed PIN access without cards or management software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"color: #353782;\"\u003e\u003cstrong\u003eRosslare AC-Q41HB Standalone PIN Controller\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRosslare AC-Q41HB\u003c\/strong\u003e combines a 3 × 4 blue-backlit metal keypad and a standalone single-door controller in one anti-vandal unit. It stores up to 500 users and is programmed locally at the keypad, making it suitable for sites that need straightforward PIN access without a separate access-control server.\u003c\/p\u003e\n\u003cdiv style=\"border-left: 4px solid #d6a500; background: #fff8dc; padding: 14px 16px; margin: 20px 0;\"\u003e\n  \u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e This is the PIN-only AC-Q41HB model. It does not contain a proximity reader and cannot use access cards or fobs. For PIN plus 125 kHz proximity access, consider the \u003ca href=\"\/products\/rosslare-standalone-3x4-pin-keypad-pin-proximity-backlit-vandal-resistant-rear-cable-acq42sb\"\u003eRosslare AC-Q42SB\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"color: #353782;\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eStandalone control for one door with up to 500 PIN users\u003c\/li\u003e\n  \u003cli\u003eFour-to-eight-digit PIN codes\u003c\/li\u003e\n  \u003cli\u003eThree operating modes: Normal, Bypass and Secure\u003c\/li\u003e\n  \u003cli\u003eNormal, Secure and Master user levels\u003c\/li\u003e\n  \u003cli\u003eBlue-backlit 3 × 4 metal keypad with two tri-colour status LEDs and sounder\u003c\/li\u003e\n  \u003cli\u003eTimed lockout after three incorrect code attempts\u003c\/li\u003e\n  \u003cli\u003eOptical back tamper and built-in heater for cold conditions\u003c\/li\u003e\n  \u003cli\u003eIP54-rated metal housing for sheltered outdoor or indoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #353782;\"\u003e\u003cstrong\u003eDoor Control and Inputs\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e2 A Form C lock relay with normally open and normally closed contacts\u003c\/li\u003e\n  \u003cli\u003eSupports correctly configured fail-safe or fail-secure locking hardware\u003c\/li\u003e\n  \u003cli\u003e2 A Form C auxiliary relay with programmable functions\u003c\/li\u003e\n  \u003cli\u003eNormally open request-to-exit input\u003c\/li\u003e\n  \u003cli\u003eNormally open auxiliary input with ten programmable modes\u003c\/li\u003e\n  \u003cli\u003eDoor Ajar, Forced, Shunt, Monitor and Secure functions\u003c\/li\u003e\n  \u003cli\u003eOptional doorbell operation through the keypad’s asterisk key when used with a compatible Rosslare BL-D40\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #353782;\"\u003e\u003cstrong\u003ePower and Professional Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe AC-Q41HB requires a regulated \u003cstrong\u003e12–24 V DC\u003c\/strong\u003e power supply or a \u003cstrong\u003e16–24 V AC\u003c\/strong\u003e transformer. At 12 V DC it draws approximately 70 mA in standby and 130 mA maximum with the heater off, or 550 mA in standby and 610 mA maximum with the heater operating.\u003c\/p\u003e\n\u003cp\u003eThe power supply must be sized for the keypad, electric lock and any connected accessories. The lock type, relay configuration and fire or emergency-release requirements must also be assessed for the door.\u003c\/p\u003e\n\u003cp\u003eBecause the controller and relays are located at the keypad, a higher-security door may require a split controller architecture that keeps the lock relay on the secure side. Professional low-voltage installation and commissioning are recommended.\u003c\/p\u003e\n\u003ch2 style=\"color: #353782;\"\u003e\u003cstrong\u003eWhat’s Included\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOne Rosslare AC-Q41HB standalone PIN keypad controller\u003c\/li\u003e\n  \u003cli\u003eProduct documentation available from the Downloads section\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #353782;\"\u003e\u003cstrong\u003eWhat’s Not Included\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePower supply or transformer\u003c\/li\u003e\n  \u003cli\u003eElectric strike, magnetic lock or other locking hardware\u003c\/li\u003e\n  \u003cli\u003eExit button, door contact, cabling or enclosure\u003c\/li\u003e\n  \u003cli\u003eRosslare BL-D40 doorbell accessory\u003c\/li\u003e\n  \u003cli\u003eAccess cards or fobs; this model is PIN only\u003c\/li\u003e\n  \u003cli\u003eInstallation, programming or commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #353782;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003eAC-Q41HB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eCredential type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003ePIN only\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eUser capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e500 users\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003ePIN length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e4–8 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e12–24 V DC regulated or 16–24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eRelay outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003eTwo 2 A Form C relays\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eEnvironmental rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e−20°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eOperating humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e0–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border-bottom: 1px solid #ddd;\"\u003e120 × 76 × 27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eApproximately 440 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #353782;\"\u003e\u003cstrong\u003eDelivery and Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eCTC Communications delivers the AC-Q41HB Australia wide. Browse compatible \u003ca href=\"\/collections\/security-accessories-door-locks\"\u003edoor locks\u003c\/a\u003e and \u003ca href=\"\/collections\/security-accessories-exit-button\"\u003eexit buttons\u003c\/a\u003e, or view the wider \u003ca href=\"\/collections\/rosslare\"\u003eRosslare range\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eFor suitable Sydney projects, CTC can assist with professional access-control installation and commissioning. \u003ca href=\"\/pages\/request-a-quote\"\u003eRequest a quote\u003c\/a\u003e with the door type, lock type and site location.\u003c\/p\u003e","brand":"Rosslare","offers":[{"title":"Default Title","offer_id":41782050226360,"sku":"ROSAC-Q41HB","price":173.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/5834\/8216\/files\/Rosslare_AC-Q41HB_Standalone_PIN_Keypad.webp?v=1789943433","url":"https:\/\/www.ctccommunications.com.au\/products\/rosslare-ac-q41hb-standalone-pin-keypad","provider":"CTC Communications","version":"1.0","type":"link"}