Best For: Commercial offices, controlled staff entrances and secure internal doors requiring strong 580kg fail-safe magnetic locking without door or lock status monitoring.
FSH FEM6600 Standard Single Magnetic Door Lock – Non-Monitored, 580kg, 12/24V DC
The FSH FEM6600 is a standard single electromagnetic door lock designed for commercial access control installations requiring strong and reliable fail-safe locking. It provides a holding strength of up to 580kg and supports field-selectable 12V or 24V DC operation.
This non-monitored magnetic lock operates in Power To Lock mode and releases when electrical power is removed. It is suitable for compatible access control panels, intercom systems, card readers, keypads and door controllers where lock and door status feedback is not required.
Key Features of the FSH FEM6600
- Standard single electromagnetic door lock
- Up to 580kg holding strength
- Non-monitored configuration without LSS or DSS outputs
- Fail-safe, Power To Lock operation
- Field-selectable 12V or 24V DC input
- Surface-mount installation
- Built-in MOV surge protection
- No residual magnetism when power is removed
- Satin anodised aluminium housing
- Zinc-plated electromagnetic lock body
- Carbon-free steel armature plate
- Fire tested for up to 2 hours
- Five-year mechanical and electronic manufacturer warranty
Strong 580kg Magnetic Holding Force
With up to 580kg holding strength, the FEM6600 provides dependable electromagnetic locking for commercial doors requiring greater security than a standard slimline magnetic lock.
The full-sized magnet and armature plate create a strong connection when correctly installed and aligned, making this model suitable for controlled commercial entrances, offices and restricted staff areas.
Non-Monitored Configuration
The FSH FEM6600 is the non-monitored single-door model in the FEM6600 Series. It does not include:
- Lock Status Sensor (LSS)
- Door Status Sensor (DSS)
- Red and green LED status indication
- Remote door or lock status outputs
Where monitoring and visual status indication are required, the corresponding monitored single-door model is the FSH FEM6600M.
Fail-Safe Magnetic Locking
The FEM6600 operates in fail-safe or Power To Lock mode. Electrical power is applied to secure the door, and the magnetic lock releases when power is removed.
This operating method allows the lock to be integrated with compatible access control panels, emergency exit devices, break-glass units and fire-alarm interfaces. Emergency egress requirements must be considered when designing the complete door locking system.
Dual-Voltage 12/24V DC Operation
Field-selectable 12V or 24V DC operation provides flexibility when connecting the FEM6600 to commercial access control power supplies.
-
12V DC: approximately 500mA
-
24V DC: approximately 250mA
The power supply should be sized to accommodate the magnetic lock, access control panel and any other connected equipment.
No Residual Magnetism
The FEM6600 is designed without residual magnetism after power is removed. This helps the door release cleanly following an authorised access request, emergency release or interruption to the power supply.
Technical Specifications
| Brand |
FSH |
| Model |
FEM6600 / FSHFEM6600 |
| Series |
FEM6600 Series |
| Product Type |
Standard single electromagnetic door lock |
| Door Configuration |
Single door |
| Monitoring |
Non-monitored |
| Holding Strength |
Up to 580kg |
| Operation |
Fail safe / Power To Lock |
| Input Voltage |
12V or 24V DC, field selectable |
| Current Draw |
500mA at 12V DC / 250mA at 24V DC |
| Mounting |
Surface mount |
| Magnet Dimensions |
268mm x 73mm x 40mm |
| Armature Plate Dimensions |
190mm x 61mm x 16mm |
| Housing |
Satin anodised aluminium |
| Electromagnetic Body |
Zinc plated |
| Surge Protection |
Built-in MOV protection |
| Fire Rating |
Up to 2 hours in accordance with AS 1905.1:2015, subject to the approved doorset |
| Approvals |
CE and C-Tick |
| Warranty |
Five-year mechanical and electronic manufacturer warranty |
Ideal Applications
- Commercial office entrances
- Controlled staff doors
- Retail and administration buildings
- Restricted internal areas
- Education and healthcare facilities
- Apartment and shared-building entrances
- Access control systems not requiring monitoring outputs
Fire-Rated Door Applications
The FEM6600 has been tested for use on compatible fire-door assemblies for up to two hours in accordance with AS 1905.1:2015. Suitability depends on the complete doorset, mounting arrangement and fire-door manufacturer requirements.
Approval must be confirmed before installing the magnetic lock on a fire-rated door.
Installation Note
The FSH FEM6600 should be installed by a qualified security or access control technician. Door alignment, mounting brackets, power supply capacity, cable protection, emergency release devices and fire-alarm integration must be considered during system design.
An appropriate L&Z bracket may be required where the door and frame configuration does not support standard direct mounting.
Why Choose the FSH FEM6600?
- Strong 580kg electromagnetic holding force
- Commercial-grade single-door locking
- Flexible 12V or 24V DC operation
- Fail-safe operation for access-controlled exits
- Clean release without residual magnetism
- Built-in surge protection
- Fire tested for up to two hours