System Sensor 2012/24AUSI Photoelectric Smoke Alarm

SKU FIRE025-2012/24
Availability:
In stock

The System Sensor 2012/24AUSI is a four-wire photoelectric smoke alarm for compatible 12/24 V DC security and building systems.

  • 85 dB(A) temporal sounder
  • Form C relay for alarm-panel reporting
  • Mounting base and 9 V backup battery included
  • AS 3786:2014 certified; ActivFire listing afp-3289

Professional hardwired installation required. Not a standalone battery-only or direct 240 V alarm.

Save 8% Save 8%
Original price $124.45
Original price $124.45 - Original price $124.45
Original price $124.45
Current price $114.45
$114.45 - $114.45
Current price $114.45

Shipping & Refunds

Shipping Refund Policy


System Sensor 2012/24AUSI Photoelectric Smoke Alarm

The System Sensor 2012/24AUSI is a four-wire photoelectric smoke alarm for compatible extra-low-voltage security, access-control and building systems. It combines local smoke detection with an 85 dB(A) temporal sounder, relay reporting and a 9 V backup battery.

Best For

Replacing or expanding a professionally wired 12/24 V DC alarm system that requires local warning, relay-based panel reporting and compatible smoke-alarm interconnection.

Important: This is not a wireless, battery-only or direct 240 V smoke alarm. It requires a compatible external DC power source and professional wiring. The included 9 V battery provides backup power; it does not replace the hardwired supply.

Compatibility and System Requirements

  • Designed for four-wire 12/24 V DC systems; documented operating supply range is 9–30 V DC
  • Form C changeover relay provides normally open and normally closed alarm contacts
  • Compatible with security or access-control panels that provide suitable power and a relay-input zone
  • Up to 24 compatible 2012/24AUSI alarms may be interconnected
  • Panel capacity, wiring, placement and regulatory suitability must be confirmed by the installer

Key Features

  • Photoelectric sensing for open-area smoke detection
  • Built-in 85 dB(A) sounder measured at 3 metres
  • Temporal evacuation alarm pattern
  • Test and silence button
  • Bi-colour status LED with fault and maintenance indications
  • Removable smoke chamber for inspection and cleaning
  • Low-profile white ceiling housing

Technical Specifications

Model 2012/24AUSI
Detection type Photoelectric
Supply 9–30 V DC operating range; intended for 12/24 V DC systems
Backup battery 9 V battery
Sound output 85 dB(A) at 3 m
Relay Form C, 1 A at 30 V AC/DC
Dimensions 135 mm diameter × 55 mm high
Operating temperature 0–45°C for Australian installations

What Is Included

  • System Sensor 2012/24AUSI smoke alarm
  • Mounting base/ring
  • 9 V backup battery

Not included: external DC power supply, alarm panel, cabling, fixings for every surface or installation labour.

Compliance and Installation

Product documentation lists certification to AS 3786:2014 and ActivFire listing afp-3289. Compliance depends on correct product selection, location, wiring and installation under current national, state, territory and building requirements.

Smoke alarms are life-safety equipment and should be installed, commissioned and maintained by a suitably qualified technician. CTC offers alarm installation across Sydney, with product delivery available Australia-wide.

Downloads



Reviews
Flat Rate Shipping $19.99
Standard delivery across Australia
Free Delivery Over $850
No shipping fees on qualifying orders
Australia Wide Shipping
We deliver to all states and territories

Why Choose CTC Communications?

  • In Business Since 1993
  • 30+ Years Industry Experience
  • ASIAL & ISO Certified
  • NSW Licensed Security Installer
  • Sydney-Wide Professional Installation
  • Genuine Products no Grey Market
  • Manufacturer & Installation Warranty
  • Compliant with Australian Security Standards