Best For: Double commercial doors, office entrances and controlled access points requiring strong fail-safe magnetic locking without door or lock status monitoring.
FSH FEM6600D Standard Double Magnetic Door Lock – Non-Monitored, 580kg, 12/24V DC
The FSH FEM6600D is a standard double electromagnetic door lock designed for commercial access control installations requiring strong fail-safe locking across two door leaves. It incorporates two magnetic locks, with each magnet providing a holding strength of up to 580kg.
Operating from field-selectable 12V or 24V DC power, the FEM6600D provides fail-safe, Power To Lock operation and releases both doors when electrical power is removed. It is suitable for compatible access control panels, intercom systems, card readers, keypads and door controllers where monitoring outputs are not required.
Key Features of the FSH FEM6600D
- Standard double electromagnetic door lock
- Up to 580kg holding strength per magnetic lock
- Two magnetic locks for paired door leaves
- Non-monitored configuration without LSS or DSS outputs
- Fail-safe, Power To Lock operation
- Field-selectable 12V or 24V DC input
- Surface-mount installation
- Built-in MOV surge protection
- No residual magnetism when power is removed
- Satin anodised aluminium housing
- Zinc-plated electromagnetic lock bodies
- Two carbon-free steel armature plates
- Fire tested for up to 2 hours
- Five-year mechanical and electronic manufacturer warranty
High-Strength Locking for Double Doors
The FEM6600D combines two full-sized electromagnetic locks within a single double-door housing. Each magnet operates with its own armature plate and provides up to 580kg holding strength for the corresponding door leaf.
This configuration is suitable for wider commercial entrances where both doors must be secured through the same access control system.
Non-Monitored Configuration
The FSH FEM6600D is the non-monitored double-door model in the FEM6600 Series. It does not include:
- Lock Status Sensor (LSS)
- Door Status Sensor (DSS)
- Red and green LED status indication
- Remote door or lock status outputs
Where monitoring and visual status indication are required, the corresponding monitored model is the FSH FEM6600DM.
Fail-Safe Magnetic Locking
The FEM6600D operates in fail-safe or Power To Lock mode. Electrical power is applied to secure both door leaves, and the magnetic locks release when power is removed.
This allows the lock to be integrated with compatible emergency exit devices, break-glass units, access control panels and fire-alarm interfaces. Emergency egress requirements must be considered when designing the complete door locking system.
Dual-Voltage 12/24V DC Operation
Field-selectable 12V or 24V DC operation provides flexibility when connecting the FEM6600D to commercial access control power supplies.
Each magnetic lock draws approximately:
- 500mA at 12V DC
- 250mA at 24V DC
For the complete double lock, allow approximately 1A at 12V DC or 500mA at 24V DC. The power supply must also accommodate the access controller and any other connected devices.
No Residual Magnetism
The FEM6600D is designed without residual magnetism after power is removed. This helps both door leaves release cleanly following an authorised access request, emergency release or interruption to the power supply.
Technical Specifications
| Brand |
FSH |
| Model |
FEM6600D / FSHFEM6600D |
| Series |
FEM6600 Series |
| Product Type |
Standard double electromagnetic door lock |
| Door Configuration |
Double door |
| Monitoring |
Non-monitored |
| Holding Strength |
Up to 580kg per magnetic lock |
| Operation |
Fail safe / Power To Lock |
| Input Voltage |
12V or 24V DC, field selectable |
| Total Current Draw |
Approximately 1A at 12V DC / 500mA at 24V DC |
| Mounting |
Surface mount |
| Magnet Dimensions |
535mm x 73mm x 40mm |
| Armature Plate Dimensions |
190mm x 61mm x 16mm – two supplied |
| Housing |
Satin anodised aluminium |
| Electromagnetic Bodies |
Zinc plated |
| Surge Protection |
Built-in MOV protection |
| Fire Rating |
Up to 2 hours in accordance with AS 1905.1:2015, subject to the approved doorset |
| Approvals |
CE and C-Tick |
| Warranty |
Five-year mechanical and electronic manufacturer warranty |
Ideal Applications
- Double commercial entry doors
- Office and administration buildings
- Controlled staff entrances
- Retail premises and shopping centres
- Education and healthcare facilities
- Apartment and shared-building entrances
- Access control systems not requiring monitoring outputs
Fire-Rated Door Applications
The FEM6600D has been tested for use on compatible fire-door assemblies for up to two hours in accordance with AS 1905.1:2015. Suitability depends on the complete doorset, mounting arrangement and fire-door manufacturer requirements.
Approval must be confirmed before installing the magnetic lock on fire-rated doors.
Installation Note
The FSH FEM6600D should be installed by a qualified security or access control technician. Door alignment, mounting brackets, power supply capacity, cable protection, emergency release devices and fire-alarm integration must be considered during system design.
An appropriate double L&Z bracket may be required where the doors and frame do not support standard direct mounting.
Why Choose the FSH FEM6600D?
- High-strength electromagnetic locking for double doors
- Up to 580kg holding strength per door leaf
- Flexible 12V or 24V DC operation
- Fail-safe operation for access-controlled exits
- Clean release without residual magnetism
- Built-in MOV surge protection
- Fire tested for up to two hours
- Five-year mechanical and electronic warranty
Shop CTC Communications for quality FSH electronic locking products, magnetic door locks and access control locking accessories.
Not sure which FSH lock is right for your door?
Compare electric strikes, magnetic locks, monitored models, holding strengths and mounting options in our
FSH Electric Door Locks Buying Guide.